Description
  • Organic vapour filter class A2 (high capacity).
Material
  • Plastic polypropylene. No metal parts.
Usage
  • Used against organic gas and vapour with a boiling point above +65°C,such as solvents.
  • The filter fits into the filter attachment of Sundström's half and full face masks.
  • An SR510 particle filter can be snapped onto the front of the filter.
Size
  • Largest diameter: 106 mm
  • Thickness: 36 mm
Weight
  • 137 g
Carbon
  • The filter contains 100 g of activated carbon.
Adsorption capacity
  • In tests with 5,000 ppm carbon tetrachloride at 30 l/min, the filter lasts for 45-50 minutes (standards requirements: >40 min)
  • The filter absorbs approximately 42-45 g (1.5-1.6 oz) carbon tetrachloride (standards requirements: >38.4 g (>1.36 oz))
Pressure drop
  • At 30 l/min: 25-30 Pa (standards requrement: <100 Pa)
  • At 95 l/min: 120-140 Pa (standards requirement: <400 Pa)
Storage
  • Store at room temperature in clean, dry place.
  • If seal has been broken, store away from contaminants in an air-tight container.
  • Shelf life is 5 years if seal is unbroken. Expiry date printed on filter.

(SR218)

SKU SR218
Brand Sundstrom
Shipping Weight 0.1300kg
Shipping Width 0.120m
Shipping Height 0.080m
Shipping Length 0.120m
Shipping Cubic 0.001152000m3
Unit Of Measure ea

Be The First To Review This Product!

Help other Combined Safety Solutions users shop smarter by writing reviews for products you have purchased.